{"product_id":"herco-uo-d-900-fu","title":"Herco UO-D 900 FU","description":"\u003cp\u003e\u003cspan\u003eFor desalination of softened drinking water according to drinking water regulations (free chlorine not detectable). Up to 30% energy savings due to high pressure pump with frequency converter (FU) with control of permeate flow rate at constant value (PKR). Particularly quiet operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFeatures:\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSkid mounted, complete unit\u003c\/li\u003e\n\u003cli\u003eParticularly space-saving (610 x 810 x 1800 mm)\u003c\/li\u003e\n\u003cli\u003eRO digital controller\u003c\/li\u003e\n\u003cli\u003eRecovery from 75% to 80%\u003c\/li\u003e\n\u003cli\u003eSalt rejection percentage: min. 97%\u003c\/li\u003e\n\u003cli\u003eWorking pressure: 14 bar\u003c\/li\u003e\n\u003cli\u003eDigital flow meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAdvantages of the FU version:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEnergy saving of 30 - 50 % compared to RO units without VSD\u003c\/li\u003e\n\u003cli\u003eAutomatic regulation PKR for constant permeate rates even at fluctuating operating conditions included\u003c\/li\u003e\n\u003cli\u003eParticularly quiet operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"gvi gvi-name-value font-name-value\" id=\"specifications-table\" data-specification-url=\"\/variantinfo\/getinfo\" data-productid=\"5110010188\"\u003e\n\u003ctbody\u003e\n\u003ctr data-featurename=\"WidthMM\" data-emptyrow=\"False\" data-unit=\"mm\"\u003e\n\u003ctd class=\"name\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e605 \u003cspan class=\"value\"\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"HeightMM\" data-emptyrow=\"False\" data-unit=\"mm\"\u003e\n\u003ctd class=\"name\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e1810 \u003cspan class=\"value\"\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"DepthMM\" data-emptyrow=\"False\" data-unit=\"mm\"\u003e\n\u003ctd class=\"name\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e810 \u003cspan class=\"value\"\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"kg\"\u003e\n\u003ctd class=\"name\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e160 \u003cspan class=\"value\"\u003ekg\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"l\/h\"\u003e\n\u003ctd class=\"name\"\u003ePermeate Flow\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e900 \u003cspan class=\"value\"\u003el\/h\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eMembranes\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e4040 x 3\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eController\u003c\/td\u003e\n\u003ctd class=\"value\"\u003eRO digital\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"%\"\u003e\n\u003ctd class=\"name\"\u003eRecovery\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e75 - 80 \u003cspan class=\"value\"\u003e%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"bar\"\u003e\n\u003ctd class=\"name\"\u003eMax Operating Pressure\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e14 \u003cspan class=\"value\"\u003ebar\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eFeedwater Connection\u003c\/td\u003e\n\u003ctd class=\"value\"\u003eDN20\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003ePermeate\/Concentrate Connection\u003c\/td\u003e\n\u003ctd class=\"value\"\u003eDN20\/15\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e3 x 400V \/ 50Hz\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"Kw\"\u003e\n\u003ctd class=\"name\"\u003eMotor Power\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e1.5 \u003cspan class=\"value\"\u003eKw\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"%\"\u003e\n\u003ctd class=\"name\"\u003eMinimal Salt Rejection\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e97 \u003cspan class=\"value\"\u003e%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"A\"\u003e\n\u003ctd class=\"name\"\u003ePre-fusing\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e20 \u003cspan class=\"value\"\u003eA\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eConductivity Range\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e1 - 999 µS\/cm\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eFeedwater Pressure\u003c\/td\u003e\n\u003ctd class=\"value\"\u003emin.\/max. 2\/6 bar\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eFeedwater Temperature\u003c\/td\u003e\n\u003ctd class=\"value\"\u003emin.\/max. 5\/35 °c\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd class=\"value\"\u003eMax. 40°c\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003epH Range\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e3 - 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eNotes:\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe unit is designed for a maximum TDS of 1,000 mg\/l, a water temperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the unit still reaches design permeate flow after three years of operation. The permeate recovery depends on the raw water quality and the type of pretreatment.\u003c\/span\u003e\u003c\/p\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":57729338147189,"sku":null,"price":14430.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/8553\/5774\/files\/Herco_UO-D_FU_Range.png?v=1793955786","url":"https:\/\/waterwisepumps.co.uk\/products\/herco-uo-d-900-fu","provider":"Waterwise Pumps","version":"1.0","type":"link"}