{"product_id":"herco-uo-d-300-cd-reverse-osmosis-system-with-duplex-softener","title":"Herco UO-D 300 CD Reverse Osmosis System with Duplex Softener","description":"\u003cp\u003eReady-to-connect system in compact design including pre-treatment for desalination of drinking water according to drinking water regulations (free chlorine not detectable).\u003c\/p\u003e\n\u003cp\u003eDue to integrated water pre-treatment components as pre-filter, backflow preventer, duplex water softener and limitron hardness monitoring unit a piping on site is not necessary. Easiest on site-installation due to only 4 connections (drinking water, permeate, waste water and power socket).\u003c\/p\u003e\n\u003ch2\u003eFeatures:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSkid mounted, complete unit (1130 x 780 x 1520mm)\u003c\/li\u003e\n\u003cli\u003eDuplex softener Clack CI Twin 2 x 30L mono resins\u003c\/li\u003e\n\u003cli\u003eRO digital controller\u003c\/li\u003e\n\u003cli\u003eRecovery from 75% to 80%\u003c\/li\u003e\n\u003cli\u003eSalt rejection percentage: min. 97%\u003c\/li\u003e\n\u003cli\u003eWorking pressure: 12 bar\u003c\/li\u003e\n\u003cli\u003eVoltage: 230 V\/50 Hz\u003c\/li\u003e\n\u003cli\u003eDigital flow meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"gvi gvi-name-value font-name-value\" id=\"specifications-table\" data-specification-url=\"\/variantinfo\/getinfo\" data-productid=\"5110010182\"\u003e\n\u003ctbody\u003e\n\u003ctr data-featurename=\"WidthMM\" data-emptyrow=\"False\" data-unit=\"mm\"\u003e\n\u003ctd class=\"name\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e1130 \u003cspan class=\"value\"\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"HeightMM\" data-emptyrow=\"False\" data-unit=\"mm\"\u003e\n\u003ctd class=\"name\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e1520 \u003cspan class=\"value\"\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"DepthMM\" data-emptyrow=\"False\" data-unit=\"mm\"\u003e\n\u003ctd class=\"name\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e780 \u003cspan class=\"value\"\u003emm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"kg\"\u003e\n\u003ctd class=\"name\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e175 \u003cspan class=\"value\"\u003ekg\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"l\/h\"\u003e\n\u003ctd class=\"name\"\u003ePermeate Flow\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e300 \u003cspan class=\"value\"\u003el\/h\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eMembranes\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e4040 x 1\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eController\u003c\/td\u003e\n\u003ctd class=\"value\"\u003eRO digital\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"%\"\u003e\n\u003ctd class=\"name\"\u003eRecovery\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e75 - 80 \u003cspan class=\"value\"\u003e%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"bar\"\u003e\n\u003ctd class=\"name\"\u003eMax Operating Pressure\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e12 \u003cspan class=\"value\"\u003ebar\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eFeedwater Connection\u003c\/td\u003e\n\u003ctd class=\"value\"\u003eDN20\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003ePermeate\/Concentrate Connection\u003c\/td\u003e\n\u003ctd class=\"value\"\u003eDN10\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e230V \/ 50Hz\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"Kw\"\u003e\n\u003ctd class=\"name\"\u003eMotor Power\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e0.55 \u003cspan class=\"value\"\u003eKw\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"%\"\u003e\n\u003ctd class=\"name\"\u003eMinimal Salt Rejection\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e97 \u003cspan class=\"value\"\u003e%\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"A\"\u003e\n\u003ctd class=\"name\"\u003ePre-fusing\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e16 \u003cspan class=\"value\"\u003eA\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eConductivity Range\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e1 - 999 µS\/cm\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eFeedwater Pressure\u003c\/td\u003e\n\u003ctd class=\"value\"\u003emin.\/max. 4\/6 bar\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eFeedwater Temperature\u003c\/td\u003e\n\u003ctd class=\"value\"\u003emin.\/max. 5\/35 °c\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd class=\"value\"\u003eMax. 40°c\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003epH Range\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e3 - 11\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"\"\u003e\n\u003ctd class=\"name\"\u003eWaste Water Connection\u003c\/td\u003e\n\u003ctd class=\"value\"\u003eHT 50\u003cspan class=\"value\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"°dH x m³\"\u003e\n\u003ctd class=\"name\"\u003eCapacity of softener\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e120 \u003cspan class=\"value\"\u003e°dH x m³\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-featurename=\"\" data-emptyrow=\"False\" data-unit=\"°dH\"\u003e\n\u003ctd class=\"name\"\u003eMax. Raw Water Hardness In Continuous Operation\u003c\/td\u003e\n\u003ctd class=\"value\"\u003e35 \u003cspan class=\"value\"\u003e°dH\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003eNotes:\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe unit is designed for a maximum TDS of 1,000 mg\/l, a water temperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the unit still reaches design permeate flow after three years of operation. The permeate recovery depends on the raw water quality and the type of pre-treatment.\u003c\/span\u003e\u003c\/p\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":57723912159605,"sku":null,"price":10245.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/8553\/5774\/files\/Herco_UO-D_120_300_CD_Reverse_Osmosis_System_with_Duplex_Softener.png?v=1793796995","url":"https:\/\/waterwisepumps.co.uk\/products\/herco-uo-d-300-cd-reverse-osmosis-system-with-duplex-softener","provider":"Waterwise Pumps","version":"1.0","type":"link"}