{"product_id":"charles-austen-enviro-0-55w-side-channel-blower-single-phase-scb4-47-0-55kw-1ph","title":"Charles Austen Enviro 0.55W Side Channel Blower (Single-Phase)| SCB4-47-0.55KW-1PH","description":"\u003cdiv\u003e\n\u003cp\u003eThe SCB4-47 0.55kW Single Phase Side Channel Blower is a compact, energy-efficient regenerative blower designed for continuous-duty air movement applications. Delivering up to 47m³\/hr free airflow and a maximum operating pressure of 290mbar(g), this blower is ideal for sewage treatment plants, aeration systems, aquaculture installations, pneumatic conveying, packaging equipment, vacuum lifting, and industrial process air applications.\u003c\/p\u003e\n\u003cp\u003ePowered by a 230V single-phase motor, the SCB4-47 offers dependable operation where a three-phase power supply is unavailable. Its oil-free design ensures clean, contamination-free airflow, making it suitable for environmental, industrial, and wastewater treatment applications. Manufactured for quiet operation and minimal maintenance requirements, the SCB4-47 combines robust construction with excellent reliability for long-term continuous service.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.55kW energy-efficient motor\u003c\/li\u003e\n\u003cli\u003e230V single-phase power supply\u003c\/li\u003e\n\u003cli\u003eMaximum airflow of 47m³\/hr\u003c\/li\u003e\n\u003cli\u003eMaximum pressure of 290mbar(g)\u003c\/li\u003e\n\u003cli\u003eOil-free, non-contact operation\u003c\/li\u003e\n\u003cli\u003eLow noise and vibration levels\u003c\/li\u003e\n\u003cli\u003eSuitable for continuous duty applications\u003c\/li\u003e\n\u003cli\u003eCompact footprint for easy installation\u003c\/li\u003e\n\u003cli\u003eMinimal maintenance requirements\u003c\/li\u003e\n\u003cli\u003eRobust industrial construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSewage treatment plant aeration\u003c\/li\u003e\n\u003cli\u003eWastewater treatment systems\u003c\/li\u003e\n\u003cli\u003eSeptic tank air injection\u003c\/li\u003e\n\u003cli\u003eFish farming and aquaculture\u003c\/li\u003e\n\u003cli\u003ePneumatic conveying\u003c\/li\u003e\n\u003cli\u003ePackaging machinery\u003c\/li\u003e\n\u003cli\u003eVacuum lifting systems\u003c\/li\u003e\n\u003cli\u003eIndustrial process air\u003c\/li\u003e\n\u003cli\u003eLaboratory equipment\u003c\/li\u003e\n\u003cli\u003eEnvironmental treatment plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe SCB4-47 is an excellent choice for smaller aeration and process air systems requiring dependable performance and low operating costs. Its oil-free technology eliminates the risk of contamination while providing the consistent airflow needed for biological treatment processes, industrial equipment, and environmental applications.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eSCB4-47 0.55kW 1PH\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSCB4-47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Power\u003c\/td\u003e\n\u003ctd\u003e0.55kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e230V Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Load Current\u003c\/td\u003e\n\u003ctd\u003e3.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Airflow\u003c\/td\u003e\n\u003ctd\u003e47m³\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd\u003e290mbar(g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Size\u003c\/td\u003e\n\u003ctd\u003e1¼\" BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Principle\u003c\/td\u003e\n\u003ctd\u003eSide Channel \/ Regenerative Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Quality\u003c\/td\u003e\n\u003ctd\u003eOil-Free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003ctable class=\"___h4t1f90 f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 f1y24664 f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i f8u40bk f1sdlqf5 ffufd3x fe1ov7n f1004tna fcoaxci fh0ee9u f15v23i2 f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eFLC (A)\u003c\/th\u003e\n\u003cth\u003eAir Flow (Max)\u003c\/th\u003e\n\u003cth\u003ePressure (Max)\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCB4-47\u003c\/td\u003e\n\u003ctd\u003e0.55kW\u003c\/td\u003e\n\u003ctd\u003e230V 1PH\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003ctd\u003e47 m³\/hr\u003c\/td\u003e\n\u003ctd\u003e290 mbar(g)\u003c\/td\u003e\n\u003ctd\u003e1¼\" BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCB2-100\u003c\/td\u003e\n\u003ctd\u003e0.70kW\u003c\/td\u003e\n\u003ctd\u003e230V 1PH\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003ctd\u003e100 m³\/hr\u003c\/td\u003e\n\u003ctd\u003e150 mbar(g)\u003c\/td\u003e\n\u003ctd\u003e1¼\" BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCB2-145\u003c\/td\u003e\n\u003ctd\u003e0.80kW\u003c\/td\u003e\n\u003ctd\u003e230V 1PH\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e145 m³\/hr\u003c\/td\u003e\n\u003ctd\u003e160 mbar(g)\u003c\/td\u003e\n\u003ctd\u003e1½\" BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCB4-66\u003c\/td\u003e\n\u003ctd\u003e0.94kW\u003c\/td\u003e\n\u003ctd\u003e230V 1PH\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003ctd\u003e66 m³\/hr\u003c\/td\u003e\n\u003ctd\u003e350 mbar(g)\u003c\/td\u003e\n\u003ctd\u003e1¼\" BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCB4-87\u003c\/td\u003e\n\u003ctd\u003e1.10kW\u003c\/td\u003e\n\u003ctd\u003e230V 1PH\u003c\/td\u003e\n\u003ctd\u003e6.8\u003c\/td\u003e\n\u003ctd\u003e87 m³\/hr\u003c\/td\u003e\n\u003ctd\u003e380 mbar(g)\u003c\/td\u003e\n\u003ctd\u003e1¼\" BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCB2-150\u003c\/td\u003e\n\u003ctd\u003e1.50kW\u003c\/td\u003e\n\u003ctd\u003e230V 1PH\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003ctd\u003e150 m³\/hr\u003c\/td\u003e\n\u003ctd\u003e290 mbar(g)\u003c\/td\u003e\n\u003ctd\u003e1½\" BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 7.62112%; text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0757\/8553\/5774\/files\/PDF_Icon_ca5cd860-4040-4582-9380-0134f2cb59d5.png?v=1774881121\" width=\"32\" height=\"32\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 92.0861%;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Enviro_SCB_Series_-_Single_Phase_Datasheet_1.pdf?v=1795091466\" target=\"_blank\" title=\"Charles Austen Enviro Single phase blower data sheet\" rel=\"noopener\"\u003eData Sheet\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Charles Austen","offers":[{"title":"Default Title","offer_id":57792191594869,"sku":null,"price":529.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/8553\/5774\/files\/Charles_Austen_Enviro_single_phase_side_channel_blower.webp?v=1795173842","url":"https:\/\/waterwisepumps.co.uk\/products\/charles-austen-enviro-0-55w-side-channel-blower-single-phase-scb4-47-0-55kw-1ph","provider":"Waterwise Pumps","version":"1.0","type":"link"}